ISOLARAUTOSAR, ISOLAR-A, ISOLAR-BFAQ / Use CaseISOLAR-A: Create and map many RTE Ports for CAN ISOLAR-A: Create and map many RTE Ports for CAN

After DBC import you manually create hundreds of signals one by one, and then map each one to a port one by one? In this article, Steffen Roser (Support Engineer at ETAS), provides a simple algorithm regarding how to automate this use case with ISOLAR. 

2018/06/04
Middleware Solution, RTARTA-OSFAQ / Use CaseRTA-OS: Convert the rate of change for ticks to time units RTA-OS: Convert the rate of change for ticks to time units

The stopwatch returns ticks and any values reported by RTA-OS are in terms of ticks on the stopwatch time base. In this article, Steffen Roser (Support Engineer at ETAS) shows you what you can do to convert this stopwatch measurements into ‘clock time’ units like milliseconds, microseconds etc.

2018/05/31
ISOLAR, RTAAUTOSAR, ISOLAR-A, ISOLAR-B, RTA-RTEFAQ / Use CaseISOLAR - ASW4X_GEN_0005 - For the ..., the references ... are proxy. ISOLAR - ASW4X_GEN_0005 - For the ..., the references ... are proxy.

After AUTOSAR code validation ISOLAR may report errors like: "ASW4X_GEN_0005 - For the ..., the references ... are proxy." In this article, Steffen Roser (Support Engineer at ETAS) describes possible root causes and how to fix them.

2018/05/24
ISOLAR, RTAAUTOSAR, ISOLAR-A, ISOLAR-B, RTA-RTEFAQ / Use CaseISOLAR - ASW4X_IB_0006 Constr_2031-In SwcInternalBehavior ..., the value of the attribute ... ISOLAR - ASW4X_IB_0006 Constr_2031-In SwcInternalBehavior ..., the value of the attribute ... 

In case the validation of an AUTOSAR project gives you the error 'Constr_2031-In SwcInternalBehavior ...': In this article, Steffen Roser (Support Engineer at ETAS) shows you how to fix it.

2018/05/24
INTECRIOINTECRIOFAQ / Use CaseINTECRIO: Start a script automatically after a2l generation INTECRIO: Start a script automatically after a2l generation

When you want to let a script start automatically after a2l file was generated: In this article, Steffen Roser (Support Engineer at ETAS) describes a simple example customization to help you getting started.

2018/05/17
ASCETASCET V6.0, ASCET V6.1, ASCET V6.2, ASCET V6.3, ASCET V6.4FAQ / Use CaseASCET: Manually change generated code before compilation ASCET: Manually change generated code before compilation

In case you want to customize the build process of ASCET: In this article by Steffen Roser (Support Engineer at ETAS), you will find a simple example and pointers to further information.

2018/05/16
EHOOKS, INCA, INTECRIOEHOOKS, INCA-EIP, INTECRIOFAQ / Use CaseConfigure the format of signal names in generated a2l file Configure the format of signal names in generated a2l file

In this article, Steffen Roser (Support Engineer at ETAS) points you to the options dialog and further information.

2018/05/16
ETK / XETK / FETKETAN, XETK-S22Manual / Technical DocumentationETAN1A Data Sheet 2018/05/15
ASCETASCET V6.0, ASCET V6.1, ASCET V6.2, ASCET V6.3, ASCET V6.4FAQ / Use CaseASCET: Set value for newly created variable via API ASCET: Set value for newly created variable via API

In this article, Steffen Roser (Support Engineer at ETAS) provides an example code that sets the value of a newly created parameter in an ASCET model via ASCET API.

2018/05/10
ISOLAR, Middleware Solution, RTAAUTOSAR, ISOLAR-A, ISOLAR-B, RTA-RTEFAQ / Use CaseDBC Importer Error: The ... in ... in AUTOSAR system is not configured so that the ... in ... is empty DBC Importer Error: The ... in ... in AUTOSAR system is not configured so that the ... in ... is empty

In case there are error messages during importing a DBC file: In this article, Steffen Roser (Support Engineer at ETAS), provides further information regarding a common error message and how to fix it.

2018/05/10
ISOLAR, Middleware Solution, RTAAUTOSAR, ISOLAR-A, ISOLAR-B, RTA-RTEFAQ / Use CaseISOLAR - RTE Error Correction Page ISOLAR - RTE Error Correction Page

The Rte Error Correction Page let's you easily solve RTE configuration issues in ISOLAR. In this article, Steffen Roser (Support Engineer at ETAS) shows you where to find this correction page.

2018/05/10