Product Family / Category
|
Product / Topic
|
Type
|
Title
|
Date
|
ASCET | ASCET-DEVELOPER | FAQ / Use Case | ASCET-DEVELOPER - (A2EU01) Conversion of component '...' of type '...' is not supported.
ASCET-DEVELOPER - (A2EU01) Conversion of component '...' of type '...' is not supported.
Did you import an "ASCET 6 Model into ASCET Eclipse Workspace" and receive the error message "[ERR ] (A2EU01) Conversion of component '...' of type '...' is not supported."?
In this article, Steffen Roser (Support Engineer at ETAS) provides further information regarding this issue. | 04/28/2018 |
ASCET, COSYM | ASCET-DEVELOPER, COSYM | FAQ / Use Case | ASCET: How to export an ASCET model to FMU?
ASCET: How to export an ASCET model to FMU?
I heard that people are running (like crazy) after a feature in ASCET-DEVELOPER they call FMU export. In this article, Steffen Roser (Support Engineer at ETAS), provides instructions regarding how to export an ASCET model to an fmu file and how to import it in ETAS COSYM. | 04/28/2018 |
ASCET | ASCET V6.4 | Known Issue Report | ASCET Example PR590443
Please refer to the ASCET Known Issue Report for further details on this example. | 04/24/2018 |
ASCET | ASCET V6.4 | Known Issue Report | ASCET Example PR590500
Please refer to the ASCET Known Issue Report for further details on this example. | 04/24/2018 |
ASCET, INTECRIO | ASCET V6.3, ASCET V6.4, INTECRIO | FAQ / Use Case | ASCET: How to create a SCOOP-IX (".six") file for INTECRIO
ASCET: How to create a SCOOP-IX (".six") file for INTECRIO
In INTECRIO we can import SCOOP-IX files (File ending ".six"). In this article, Steffen Roser (Support Engineer at ETAS) shows how to create a six file with ASCET. | 04/14/2018 |
ASCET | ASCET V6.4, ASCET-SCM | Software | ASCET-SCM V6.4.2 Hotfix 1
ASCET-SCM V6.4.2 Hotfix 1
This hotfix contains the most current bug fixes for ASCET-SCM V6.4.2. The functionality of the bug fixes has been thoroughly tested and guaranteed. However, this hotfix has not been subject to the complete release tests of ASCET. Therefore, it is not possible to guarantee the usual high quality standards for this hotfix.
ETAS GmbH accepts no further obligation in relation to this hotfix.
If you … | 04/11/2018 |
ASCET | ASCET-DEVELOPER, ASCET-MD, ASCET-RP, ASCET-SE | FAQ / Use Case | ASCET-DEVELOPER - Where is dT?
ASCET-DEVELOPER - Where is dT?
In ASCET 6 there is a global dT variable that contains the delta time value of currently running task in seconds. In this article, Steffen Roser (Support Engineer for Software Engineering at ETAS) describes how to implement and use a similar delta time variable. | 04/10/2018 |
ASCET, INCA | ASCET V6.0, ASCET V6.1, ASCET V6.2, ASCET V6.3, ASCET V6.4, … | FAQ / Use Case | ASCET: Installation stops with bluescreen: DPC_WATCHDOG_VIOLATION
ASCET: Installation stops with bluescreen: DPC_WATCHDOG_VIOLATION
When you get a blue screen during installation of ASCET on a Windows 10 machine: In this article, Steffen Roser (Support Engineer for Software Engineering) describes the root cause and solutions for this issue. | 03/01/2018 |
ASCET | ASCET V6.2, ASCET V6.3, ASCET V6.4 | FAQ / Use Case | Check Registration Successful for Current Version
Check Registration Successful for Current Version
In case you see this dialog in ASCET: In this article, Steffen Roser (Support Engineer for Software Engineering at ETAS) shows you to to fix this behavior. | 02/27/2018 |
ASCET | ASCET V6.2, ASCET V6.3, ASCET V6.4 | FAQ / Use Case | ASCET error: XML file userSettings.xml is not valid. Root Tag expected.
ASCET error: XML file userSettings.php is not valid. Root Tag expected.
During start up of ASCET there may appear be the error message "XML file ...userSettings.php is not valid". In this article, Steffen Roser (Support Engineer for Software Engineering at ETAS), describes how to fix this issue and how to avoid this situation in future. | 02/22/2018 |
ASCET | ASCET V6.2, ASCET V6.3, ASCET V6.4 | FAQ / Use Case | ASCET Physical Experiment: How to adjust X axis of oscilloscope
ASCET Physical Experiment: How to adjust X axis of oscilloscope
The oscilloscope in ASCET's Physical Experiment displays values of a time range of 1 second per default. In this article, Steffen Roser (support engineer for software engineering at ETAS), provides instructions regarding how to adjust the time axis setting. | 02/21/2018 |