ASCETASCET V6.2, ASCET V6.3, ASCET V6.4FAQ / Use CaseBlock Diagram Editor – Image cropped at the bottom and on the right side Block Diagram Editor – Image cropped at the bottom and on the right side

You open a model in block diagram editor in ASCET. Everything looks good until you scroll to the far right and/or bottom: parts of the diagram are missing and the drawing looks like cutted/cropped.

In this article, Steffen Roser (Support Engineer at ETAS), provides information regarding the root cause and how to change the behavior.

09/12/2017
ASCETASCET V6.2, ASCET V6.3, ASCET V6.4FAQ / Use CaseConfirmation dialog missing Confirmation dialog missing

In ASCET there are a lot of confirmation dialogs and hint dialogs available.

In this article, Steffen Roser (Support Engineer at ETAS), describes how to get to the list of available confirmation and hint dialogs.

09/12/2017
ASCETASCET V6.2, ASCET V6.3, ASCET V6.4FAQ / Use Case[ ASCET ] WARNING(WMdl00): please note: the value "false" of project option "Force Parenthesis for Binary Logical Operators" is obsolete WARNING (WMdl00): please note: the value "false" of project option "Force Parenthesis for Binary Logical Operators" is obsolete

Do you receive warning messages regarding obsolete project option values when you build code from your model?

In this article, Steffen Roser (Support Engineer at ETAS), describes how to get rid of these warnings.

09/12/2017
ASCETASCET V6.2, ASCET V6.3, ASCET V6.4FAQ / Use Case[ ASCET ] ERROR (YBdl22): method must be defined; need a return value ERROR (YBdl22): method must be defined; need a return value 

When building code from ASCET model there may appear following error message:
"ERROR(YBdl22): method must be defined; need a return value".

In this article, Steffen Roser (Support Engineer at ETAS) describes how to solve this error message.

09/07/2017
ASCETASCET V6.2, ASCET V6.3, ASCET V6.4FAQ / Use Case[ ASCET ] ERROR (YBdl51): missing argument connection for method ... at block ... ERROR(YBdl51): missing argument connection for method ... at block ...

When building code from your model in ASCET, it may happen that you receive following message:
ERROR(YBdl51): missing argument connection for method at block .

In this article, Steffen Roser (Support Engineer at ETAS) describes how to fix this behaviour.

09/07/2017
ASCETASCET V6.2, ASCET V6.3, ASCET V6.4FAQ / Use Case[ ASCET ] Generation of documentation aborted. SGDummyDrawingWindow >> methodAliasName Generation of documentation aborted. SGDummyDrawingWindow>>methodAliasName 

Creating a fancy looking document from your ASCET models is easy.

Just go to Tools > Documentation. In case you get the error 'SGDummyDrawingWindow>>methodAliasName' during generation document: This behavior is fixed in ASCET V6.4.

In this article, Steffen Roser (Support Engineer at ETAS) describes a workaround.

09/07/2017
ASCETASCET V6.2, ASCET V6.3, ASCET V6.4FAQ / Use Case[ ASCET ] WARNING (WBdl9): empty sequence call at block WARNING (WBdl9): empty sequence call at block

When building code from your model in ASCET, it may happen that you receive following message: WARNING(WBdl9): empty sequence call at block .

In this article, Steffen Roser (Support Engineer at ETAS) describes how to fix this behaviour.

09/07/2017
ASCETASCET V6.2, ASCET V6.3, ASCET V6.4FAQ / Use Case[ ASCET ] WARNING (WMdl204): deprecated feature: BDE temp variables WARNING (WMdl204): deprecated feature: BDE temp variables

When generation code from ASCET model there may appear a warning regarding a deprecated feature ("BDE temp variables").

In this article, Steffen Roser (Support Engineer at ETAS) describes how to switch off this warning message.

09/07/2017
ASCETASCET V6.2, ASCET-SESoftwareASCET-SE V6.2.1 Hotfix 2

ASCET-SE V6.2.1 Hotfix 2

This hotfix contains the most current bug fixes for ASCET-SE V6.2.1. The functionality of the bug fixes has been thoroughly tested and guaranteed. However, this hotfix has not been subject to the complete release tests of ASCET. Therefore, it is not possible to guarantee the usual high quality standards for this hotfix.

ETAS GmbH accepts no further obligation in relation to this …

08/17/2017
ASCETASCET V6.4FAQ / Use CaseHow to create a System Constant in ASCET

System constants are used like constants, and also created as define statements. Unlike constants, system constants can be implemented. They are always explicitly visible in the generated code. In this article, Steffen Roser (Support Engineer for Software Engineering at ETAS), describes how to create a system constant in ASCET.

08/10/2017
ASCETASCET V6.4FAQ / Use CaseHow to create a Variant Array or Variant Matrix in ASCET

The size of an array or matrix is determined when the element is created. In addition, ASCET allows the determination of variants in array/matrix sizes via system constants. In this article, Steffen Roser (Support Engineer Software Engineering at ETAS), describes how to create a variant array or a variant matrix in ASCET.

08/10/2017