Size and Weight |
|
Dimensions (HxWxD) | 51.5 x 40 x 142 mm / 2.0 x 1.6 x 5.6 in 37.5 x 40 x 129 mm / 1.5 x 1.6 x 5.1 in (tapered rear) |
Weight | 350 g / 0.77 lb |
Environment |
|
Temperature range | -40 °C to +120 °C (-40 °F to +248 °F) (operation) |
-40 °C to +125 °C (-40 °F to +257 °F) (storage) | |
Protection class | IP67 (with cables connected) |
Altitude | Up to 5,000 m / 16,400 ft |
Tested for | Mechanical shock, vibration, fall, temperature shock, temperature alteration, storage in humidity, salt fog attack, impact from flying rocks, according to DIN EN 60068 res. ISO 16750 |
Power supply |
|
Operating voltage | 5 V to 50 V DC (-40 °C to +85 °C / -40 °F to +185 °F), |
6 V to 50 V DC (-40 °C to +120 °C / -40 °F to +248 °F) | |
Power consumption (at 12 V) | 2.1 W typ., < 25 mW (stand-by) |
Reverse voltage protection; Load dump protection | Via Cables CBEP410 / 415 / 420 / 430 / 450, CBE400 |
Host interface |
|
Ethernet connection and protocol | 100 Base-T, Full-Duplex required, XCP-on-UDP/IP |
IP address | Dynamic via INCA or configuration tool |
(default 192.168.40.44) | |
Inputs |
|
Channels | 8 |
Input measurement ranges (MR) | ±100 mV, ±1 V, ±10 V, ±60 V for differential input voltage Vin |
Over voltage protection | ±100 V continuous, all MR |
Resolution | 16 bit |
Sampling rate | 0.5 Samples/s to 10 kSamples/s, configurable per channel |
Anti-aliasing filter (in hardware) | 4th order Butterworth, 10 kHz corner frequency |
Software filter | Digital FIR Butterworth 8th order, bypass possible, 5 kHz max. corner frequency |
Electrical isolation of inputs | Channel to channel and channel to supply |
Max. common mode voltage | ±(100 V - [Vin]) channel to supply ground, [1] |
Vin ≤± 60 V | |
Input impedance | > 2 MΩ II < 2 nF (±10 V, ±60 V) |
> 10 MΩ II < 2 nF (±1 V, ±100 mV) | |
Accuracy (up to +85 °C / +185 °F) |
|
Measurement error (MR: 100 mV) | ±[0.15 % + 100 ppm/K x |T -25 °C|] x MR ±0.12 % x Vin |
Measurement error (MR: 1 V) | ±[0.05 % + 10 ppm/K x |T - 25 °C|] x MR ±0.1 % x Vin |
Measurement error (MR: 10 V) | ±[0.03 % + 5 ppm/K x |T - 25 °C|] x MR ±0.1 % x Vin |
Measurement error (MR: 60 V) | ±[0.027 % + 60 ppm/K x |T -25 °C|] x MR ±0.22 % x Vin |
Support by ETAS Software |
|
Supported by INCA V5.4.1 and up via add-on (part of ES410 delivery), INTECRIO V3.x, ES400 configuration and integration tool for XCP applications | |
Notes |
|
[1] | 60 V maximum for use inside the US. |
This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.