Technical Data

 

Size and Weight

Dimensions (HxWxD) 51.5 x 40 x 142 mm / 2.0 x 1.6 x 5.6 in
37.5 x 40 x 129 mm / 1.5 x 1.6 x 5.1 in (tapered rear)
Weight 350 g / 0.77 lb

Environment

Temperature range -40 °C to +120 °C (-40 °F to +248 °F) (operation)
-40 °C to +125 °C (-40 °F to +257 °F) (storage)
Protection class IP67 (with cables connected)
Altitude Up to 5,000 m / 16,400 ft
Tested for Mechanical shock, vibration, fall, temperature shock, temperature alteration, storage in humidity, salt fog attack, impact from flying rocks, according to DIN EN 60068 res. ISO 16750

Power supply

Operating voltage 5 V to 50 V DC (-40 °C to +85 °C / -40 °F to +185 °F),
6 V to 50 V DC (-40 °C to +120 °C / -40 °F to +248 °F)
Power consumption (at 12 V) 2.1 W typ., < 25 mW (stand-by)
Reverse voltage protection; Load dump protection Via Cables CBEP410 / 415 / 420 / 430 / 450, CBE400

Host interface

Ethernet connection and protocol 100 Base-T, Full-Duplex required, XCP-on-UDP/IP
IP address Dynamic via INCA or configuration tool
(default 192.168.40.44)

Inputs

Channels 8
Input measurement ranges (MR) ±100 mV, ±1 V, ±10 V, ±60 V for differential input voltage Vin
Over voltage protection ±100 V continuous, all MR
Resolution 16 bit
Sampling rate 0.5 Samples/s to 10 kSamples/s, configurable per channel
Anti-aliasing filter (in hardware) 4th order Butterworth, 10 kHz corner frequency
Software filter Digital FIR Butterworth 8th order, bypass possible, 5 kHz max. corner frequency
Electrical isolation of inputs Channel to channel and channel to supply
Max. common mode voltage ±(100 V - [Vin]) channel to supply ground, [1]
Vin ≤± 60 V
Input impedance > 2 MΩ II < 2 nF (±10 V, ±60 V)
> 10 MΩ II < 2 nF (±1 V, ±100 mV)

Accuracy (up to +85 °C / +185 °F)

Measurement error (MR: 100 mV) ±[0.15 % + 100 ppm/K x |T -25 °C|] x MR ±0.12 % x Vin
Measurement error (MR: 1 V) ±[0.05 % + 10 ppm/K x |T - 25 °C|] x MR ±0.1 % x Vin
Measurement error (MR: 10 V) ±[0.03 % + 5 ppm/K x |T - 25 °C|] x MR ±0.1 % x Vin
Measurement error (MR: 60 V) ±[0.027 % + 60 ppm/K x |T -25 °C|] x MR ±0.22 % x Vin

Support by ETAS Software

Supported by INCA V5.4.1 and up via add-on (part of ES410 delivery), INTECRIO V3.x, ES400 configuration and integration tool for XCP applications

Notes

[1] 60 V maximum for use inside the US.

This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.