Size and Weight |
|
Dimensions (HxWxD) | 52 x 40 x 145 mm / 2.0 x 1.6 x 5.5 in (total) 39 x 40 x 63 mm / 1.5 x 1.6 x 2.5 in (tapered rear) |
Weight | 410 g / 0.90 lb (ES413.1-OW) |
Lengths of sensor connection cables | 2x 120 mm / 4.72 in and 2x 220 mm / 8.67 in (ES413.1-OW) |
2x 150 mm / 5.91 in and 2x 250 mm / 9.84 in (ES413.1-L1B, ES413.1-L0B) | |
Environment |
|
Temperature range | -40 °C to +120 °C (-40 °F to +248 °F) (operation) -40 °C bis +125 °C (storage) |
Protection class | IP65 |
Altitude | Deployable up to 5,000 m /16,400 ft |
Power supply |
|
Operating voltage | 5 V to 50 V DC (-40 °C to +85 °C / -40 °F to +185 °F), 6 V to 50 V DC (+85 °C to +120 °C / +185 °F to +248 °F) |
Power consumption (at 12 V) | 2 W typ. (operation without sensor supply) 4.6 W max. (operation without max. sensor supply) 25 mW max. (Standby) |
Reverse voltage protection, load dump protection | Via cables CBEP410 / 415 / 420 / 425 / 430 / 450 |
Host interface |
|
Ethernet connection and protocol | 100 Base-T, Full-Duplex required, XCP-on-UDP/IP |
IP address | 192.168.40.44 (default), configurable via INCA or ES400 configuration and integration tool for XCP applications |
Inputs |
|
Channels | 4, with separate sensor supply |
Input measurement ranges (MR) | ± 100 mV, ± 1 V, ± 10 V, ± 60 V |
Sampling rate | 0,5 Samples/s to 2000 Samples/s, configurable per channel |
Anti-aliasing filter (in hardware) | Low-pass 4th order Butterworth, 10 kHz corner frequency, bypass possible |
Digital filter (Software) | Low-pass 8th order Butterworth, 1 kHz corner frequency, bypass possible |
Overvoltage protection [1] | ±100 V (Input to external overvoltage) |
Maximum isolation voltage [1] | 100 V DC (Input to input or input to supply voltage ground or housing) |
Input impedance | > 2 MΩ II < 400 pF (± 10 V, ± 60 V) > 10 MΩ II < 300 pF ( ± 1 V, ± 100 mV) |
Accuracy |
|
Resolution | 3,6 μV (MR ± 100 mV) 37,2 μV (MR: ± 1 V) 366 μV (MR: ± 10 V) 2,16 mV (MR: ± 60 V) |
Measurement error | ± (200 μV + Vin * 0,12 %) (MR: ± 100 mV) ± (1 mV + Vin * 0,1 %) (MR: ± 1 V) ± (6 mV + Vin * 0,1 %) (MR: ± 10 V) ± (36 mV + Vin * 0,22 %) (MR: ± 60 V) |
Temperature drift (-40 °C bis 85 °C) | 16 μV/K (MR: ± 100 mV) 16 μV/K (MR: ± 1 V) 70 μV/K (MR: ± 10 V) 7,2 mV/K (MR: ± 60 V) |
Temperature drift (85 °C bis 120 °C) | 300 μV/K (MR: ± 100 mV) 300 μV/K (MR: ± 1 V) 70 μV/K (MR: ± 10 V) 7,2 mV/K (MR: ± 60 V) |
Sensor supply output |
|
Output voltage | 0 V, 5 V, 8 V, 10 V, 12 V, 15 V DC, individually configurable per channel |
Accuracy of output voltage | ± 10 mV |
Output current | 30 mA max. per channel, protection against overcurrent > 200 mA |
Protection | Outputs (positive) short-circuit protected to ground and up to 26 V overvoltage. Mass is associated with operating voltage ground and protected by a fuse. |
Diagnostics | None |
Support by ETAS Software |
|
Supported by INCA V6.2.1 and higher, INCA-Add-on V1.1.12 and higher, ES400 configuration and integration tool for XCP applications V1.1.12 and higher, HSP Update-Tool V1.1.12 and higher, INTECRIO V3.2 and higher, ASCET-RP V6.1.0 and higher | |
Notes |
|
[1] | 60 V maximum for use inside the US. |
This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.