Technical Data

Size and Weight

Dimensions (HxWxD) 52 x 40 x 145 mm / 2.0 x 1.6 x 5.5 in (total)
39 x 40 x 63 mm / 1.5 x 1.6 x 2.5 in (tapered rear)
Weight 410 g / 0.90 lb (ES413.1-OW)
Lengths of sensor connection cables 2x 120 mm / 4.72 in and 2x 220 mm / 8.67 in (ES413.1-OW)
2x 150 mm / 5.91 in and 2x 250 mm / 9.84 in (ES413.1-L1B, ES413.1-L0B)

Environment

Temperature range -40 °C to +120 °C (-40 °F to +248 °F) (operation)
-40 °C bis +125 °C (storage)
Protection class IP65
Altitude Deployable up to 5,000 m /16,400 ft

Power supply

Operating voltage 5 V to 50 V DC (-40 °C to +85 °C / -40 °F to +185 °F),
6 V to 50 V DC (+85 °C to +120 °C / +185 °F to +248 °F)
Power consumption (at 12 V) 2 W typ. (operation without sensor supply)
4.6 W max. (operation without max. sensor supply)
25 mW max. (Standby)
Reverse voltage protection, load dump protection Via cables CBEP410 / 415 / 420 / 425 / 430 / 450

Host interface

Ethernet connection and protocol 100 Base-T, Full-Duplex required, XCP-on-UDP/IP
IP address 192.168.40.44 (default), configurable via INCA or ES400 configuration and integration tool for XCP applications

Inputs

Channels 4, with separate sensor supply
Input measurement ranges (MR) ± 100 mV, ± 1 V, ± 10 V, ± 60 V
Sampling rate 0,5 Samples/s to 2000 Samples/s, configurable per channel
Anti-aliasing filter (in hardware) Low-pass 4th order Butterworth, 10 kHz corner frequency,
bypass possible
Digital filter (Software) Low-pass 8th order Butterworth, 1 kHz corner frequency, bypass possible
Overvoltage protection [1] ±100 V (Input to external overvoltage)
Maximum isolation voltage [1] 100 V DC (Input to input or input to supply voltage ground or housing)
Input impedance > 2 MΩ II < 400 pF (± 10 V, ± 60 V)
> 10 MΩ II < 300 pF ( ± 1 V, ± 100 mV)

Accuracy

Resolution 3,6 μV (MR ± 100 mV)
37,2 μV (MR: ± 1 V)
366 μV (MR: ± 10 V)
2,16 mV (MR: ± 60 V)
Measurement error ± (200 μV + Vin * 0,12 %) (MR: ± 100 mV)
± (1 mV + Vin * 0,1 %) (MR: ± 1 V)
± (6 mV + Vin * 0,1 %) (MR: ± 10 V)
± (36 mV + Vin * 0,22 %) (MR: ± 60 V)
Temperature drift (-40 °C bis 85 °C) 16 μV/K (MR: ± 100 mV)
16 μV/K (MR: ± 1 V)
70 μV/K (MR: ± 10 V)
7,2 mV/K (MR: ± 60 V)
Temperature drift (85 °C bis 120 °C) 300 μV/K (MR: ± 100 mV)
300 μV/K (MR: ± 1 V)
70 μV/K (MR: ± 10 V)
7,2 mV/K (MR: ± 60 V)

Sensor supply output

Output voltage 0 V, 5 V, 8 V, 10 V, 12 V, 15 V DC, individually configurable per channel
Accuracy of output voltage ± 10 mV
Output current 30 mA max. per channel, protection against overcurrent > 200 mA
Protection Outputs (positive) short-circuit protected to ground and up to 26 V overvoltage. Mass is associated with operating voltage ground and protected by a fuse.
Diagnostics None

Support by ETAS Software

Supported by INCA V6.2.1 and higher, INCA-Add-on V1.1.12 and higher, ES400 configuration and integration tool for XCP applications V1.1.12 and higher, HSP Update-Tool V1.1.12 and higher, INTECRIO V3.2 and higher, ASCET-RP V6.1.0 and higher

Notes

[1] 60 V maximum for use inside the US.

This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.