Size and Weight |
|
Dimensions (HxWxD) | 52 x 40 x 145 mm / 2.0 x 1.6 x 5.5 in |
39 x 40 x 63 mm / 1.5 x 1.6 x 2.5 in (tapered rear) | |
Weight | 450 g / 0.99 lbs |
Lengths of sensor connection cables | 2x 125 mm / 4.92 in, 2 x 175 mm / 6.89 in, 2 x 225 mm / 8.86 in and 2x 275 mm / 10.83 in |
Environment |
|
Temperature range | -40 °C to +120 °C (-40 °F to +248 °F) (operation) |
-40 °C to +125 °C (-40 °F to +257 °F) (storage) | |
Protection class | IP65 |
Altitude | Deployable up to 5,000 m /16,400 ft |
Power supply |
|
Operating voltage | 5 V to 50 V DC (-40 °C to +85 °C / -40 °F to +185 °F), 6 V to 50 V DC (+85 °C to +120 °C / +185 °F to +248 °F) |
Power consumption (at 12 V) | 2 W typ. (operation without load) 25 mW max. (standby) |
Reverse voltage protection, load dump protection | Via cables CBEP410 / 415 / 420 / 430 / 450 |
Host interface |
|
Ethernet connection and protocol | 100 Base-T, Full-Duplex required, XCP-on-UDP/IP |
IP address | 192.168.40.44 (default), configurable via INCA or ES400 configuration and integration tool for XCP applications |
Inputs |
|
Channels | 8 |
Supported thermocouples | Type K |
Measurement Range | -200 °C to 1372 °C / -328 °F to 2502 °F |
Sampling rate | 0.1 Samples/s to 10 Samples/s, configurable per channel |
Anti-aliasing filter (in hardware) | Low-pass, one-stage, 350 Hz corner frequency |
Maximum isolation voltage [1] | 100 V DC (Input to input or input to supply voltage ground or housing) |
Input impedance | 20 MΩ II < 10 nF |
Accuracy |
|
Resolution | 100 mK |
Measurement error | ± 0,1% bzw. ± 0,5 K |
Temperature drift | ± 00,2 K/K |
Error of cold junction compensation | ± 0,8 K |
Temperature drift of cold junction compensation | ± 0,004 K/K |
Support by ETAS software |
|
Supported by INCA V6.2.1 and higher, INCA-Add-on V1.1.12 and higher, ES400 configuration and integration tool for XCP applications V1.1.12 and higher, HSP Update-Tool V1.1.12 and higher, INTECRIO V3.2 and higher, ASCET-RP V6.1.0 and higher | |
Notes |
|
[1] | 60 V maximum for use inside the US. |
This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.