Technical Data

 

Size and Weight

Dimensions (HxWxD) 51.5 x 40 x 142 mm / 2.0 x 1.6 x 5.6 in
37.5 x 40 x 129 mm / 1.5 x 1.6 x 5.1 in (tapered rear)
Weight 350 g / 0.77 lb

Environment

Temperature range -40 °C to +120 °C (-40 °F to +248 °F) (operation)
-40 °C to +125 °C (-40 °F to +257 °F) (storage)
Protection class IP67 (with cables connected)
Altitude Up to 5,000 m / 16,400 ft
Tested for Mechanical shock, vibration, fall, temperature shock, temperature alteration, storage in humidity, salt fog attack, impact from flying rocks, according to DIN EN 60068 res. ISO 16750

Power supply

Operating voltage 5 V to 50 V DC (-40 °C to +85 °C / -40 °F to +185 °F),
6 V to 50 V DC (+85 °C to +120 °C / +185 °C to +248 °F)
Reverse voltage protection; Load dump protection Via Cables CBEP410 / 415 / 420 / 430 / 450
Power consumption (at 12 V) 1.8 W typ. (operation), < 25 mW (stand-by)

Host interface

Ethernet connection and protocol 100 Base-T, Full-Duplex required, XCP-on-UDP/IP
IP address Dynamic via INCA or configuration tool (default 192.168.40.44)

Inputs

Channels 4, each with separate sensor supply
Input voltage range ±50 V
Switching thresholds Hysteresis, active and inactive level individually configurable
Switching threshold resolution 0.1 V
Glitch filter De-bouncing, configurable by software
Min. pulse width / max. signal frequency 120 ns / 4 MHz (theoret. value at 50 % duty cycle)
Time resolution 20 ns
Counter size 32 bit
Functionality Counter, frequency, duty cycle, active time, inactive time, period time, state
Combination of two channels facilitate evaluation of complex signals
Electrical isolation of inputs Channel to channel and channel to supply
Input impedance > 2 MΩ / < 250 pF
Over voltage protection ±100 V continuous
Sampling rate 0.5 Samples/s to 10 kSamples/s

Sensor supply output

Output voltage +5 V to +15 V DC or Off, individually adjustable per channel, common ground with power supply, resolution < 1 mV
Output current ≤30 mA, overcurrent protected (200 mA)

Accuracy

Ripple of sensor supply output volt-age (measurement limited to 80 MHz) < 20 mV peak to peak
Accuracy of sensor supply output voltage without load ±10 mV over the whole output voltage range

Support by ETAS Software

Supported by INCA V5.4.1 and up via add-on (part of ES441 delivery), INTECRIO V3.x, ES400 configuration and integration tool for XCP applications.

This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.