Size and Weight |
||
Dimensions (HxWxD) | 72 x 128 x 160 mm / 2.8 x 5 x 6.3 in | |
Weight | 1150 g / 2.54 lbs | |
Environment |
||
Temperature range | -40 °C to +70 °C / -40 °F to +158 °F (operation) | |
-40 °C to +85 °C / -40 °F to +185 °F (storage) | ||
Power supply |
||
Operating voltage (reverse voltage protection) | 6 V to 32 V DC, reverse-voltage protected up to 40 V, protected against load dump | |
Current consumption |
||
Continuous operation | 340 mA at 12 V | |
Stand-by | 5 mA at 12 V | |
Host interface |
||
Ethernet connection | 10 Base-T | |
Protocol | TCP/IP | |
IP address | Dynamically via INCA | |
Inputs |
||
Number of channels | 16 | |
Resolution | 16 bit, higher at slower sampling rates | |
Acquisition rate | 0.5 Samples/s to 2000 Samples/s, configurable per channel | |
Input voltage ranges | ±10 V, ±60 V | |
Input filter | Low-pass of 4th order, limit frequency 1 kHz, max. overshooting 3 % | |
Input impedance | >15 MΩ II 1 nF (±10 V); 2 MΩ II 1 nF (±60 V) | |
Measurement error | 2 mV + (U in x 0.05 %) in the ±10 V measuring range | |
12 mV + (U in x 0.05 %) in the ±60 V measuring range | ||
Temperature drift | 10 ppm/ °C, relative to input voltage | |
Electrical isolation of inputs | ±100 V channel to channel, channel to supply voltage | |
Support by ETAS Software |
||
INCA |