Technical Data

 

Size and Weight

Dimensions (HxWxD) 72 x 128 x 160 mm / 2.8 x 5 x 6.3 in
Weight 1020 g / 2.25 lbs

Environment

Temperature range -40 °C to +70 °C / -40 °F to +158 °F (operation)
-40 °C to +85 °C / -40 °F to +185 °F (storage)

Power supply

Operating voltage (reverse voltage protection) 6 V to 32 V DC, reverse-voltage protected up to 40 V, protected against load dump

Current consumption

Continuous operation 220 mA at 12 V
Stand-by 5 mA at 12 V

Host interface

Ethernet connection 10 Base-T
Protocol TCP/IP
IP address Dynamically via INCA

Inputs

Number of channels 16
Resolution 21 bit, corresponding to 0.01 °C
Acquisition rate 0.1 Samples/s to 10 Samples/s, configurable per module
Measuring range depending on thermocouple type B +250 °C to +1820 °C / +482 °F to +3308 °F
E -200 °C to +1000 °C / -328 °F to +1832 °F
J -210 °C to +1200 °C / -346 °F to +2192 °F
K -200 °C to +1372 °C / -392 °F to +2502 °F
N -200 °C to +1300 °C / -392 °F to +2372 °F
R -50 °C to +1768 °C / -58 °F to +3214 °F
S -50 °C to +1768 °C / -58 °F to +3214 °F
T -200 °C to +400 °C / -392 °F to +752 °F
Limit frequency 10 Hz
Input impedance >10 MΩ II 1 nF
Electrical isolation of inputs ±100 V channel to channel, channel to supply voltage

Accuracy [1]

Basic accuracy ΔTg depending on thermocouple type B ±(0.050 % + 5.0 K)
E ±(0.050 % + 0.2 K)
J ±(0.030 % + 0.2 K)
K ±(0.025 % + 0.25 K)
N ±(0.035 % + 0.38 K)
R ±(0.050 % + 2.0 K)
S ±(0.050 % + 2.0 K)
T ±(0.050 % + 0.3 K)
Maximum temperature drift ΔTd depending on thermocouple type B ±0.1 K/K
E ±0.004 K/K
J ±0.004 K/K
K ±0.005 K/K
N ±0.008 K/K
R ±0.04 K/K
S ±0.04 K/K
T ±0.005 K/K
Accuracy ΔTi depending on the internal resistance of the respective thermocouple at internal resistances > 50 Ω B ±0.08 K/Ω
E ±0.03 K/Ω
J ±0.003 K/Ω
K ±0.004 K/Ω
N ±0.006 K/Ω
R ±0.03 K/Ω
S ±0.03 K/Ω
T ±0.004 K/Ω
Accuracy of cold junction compensation ΔTcjc ±1 K
Maximum temperature drift of cold junction compensation ΔTdcjc ±0.008 K/K

Inputs

Maximum allowed input voltage 32 V

Support by ETAS Software

INCA

Notes

[1] Total error of a temperature measurement ΔT = ΔTg + ΔTd + ΔTi + ΔTcjc + ΔTdcjc

This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.