Size and weight |
|
Cable length | 0.20 m / 0.7 ft (to measurement point) |
0.80 m / 2.6 ft (to ES411 module) | |
Cable weight | 0.430 kg / 0.95 lb (probes included) |
Dimension of the probes | 25 mm x 88 mm / 1.0 in x 3.56 in (Ø x L) |
Environment |
|
Temperature range | -40 °C to +75 °C / -40 °F to +167 °F (Operation) |
Protection class | IP65 |
Altitude | Up to 5,000 m /16,400 ft (operation) |
Inputs |
|
Channels | 4 |
Measurement range | ±840 V (CBN400) |
±10 V (CBN401) | |
Maximum input voltage | ±840 V (below 4,000 m altitude) |
±600 V (between 4,000 m and 5,000 m altitude) | |
Isolation test voltage | ±1500 V DC (input to output) |
Isolation voltage | ±840 V DC (any input wire to UBatt-) |
Transient immunity | ±800 V/µs |
Input resistance | 12 MΩ |
Input capacitance | 4 pF (straight cables with 20 cm length, at 10 kHz) |
Coupling capacitance | 10 pF (input to output) |
Measurement accuracy including accuracy of ES411 module | CBN400: ± 0.40 V + IUinI * 0.15 % (at Tamb = 25 °C / 171 °F) |
CBN400: ± 1 V + IUinI * 0.5 % (at Tamb = - 40 °C to +75 °C / - 40 °F to 167 °F) | |
CBN401: ± 5 mV + IUinI * 0.15 % (at Tamb = 25 °C / 171 °F) | |
CBN401: ± 15 mV + IUinI * 0.5 % (at Tamb = - 40 °C to +75 °C / - 40 °F to 167 °F) | |
Recommended measurement modules |
|
ES411 - A/D Module with Sensor Supply | |
ES415 - High Definition A/D Module with Sensor Supply | |
ES441 - Counter and Frequency Measurement Module with Sensor Supply | |
System requirements |
|
Software | ES400 add-on to INCA v1.3.2 and higher |
ES400 configuration and integration tool for XCP applications v1.3.2 and higher | |
Hardware | ES4xx modules v2.0 and higher |
ES4xx modules v1.x are not compatible, but can be upgraded to v2.x at ETAS | |
Firmware | HSP v9.7.0 and higher |
This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.