Dimensions |
|
Cable length | 0.30 m / 1 ft to measurement point |
1.60 m / 5.3 ft to ES411 module | |
Probe size (Ø x L) | 26 mm x 70 mm / 1 in x 7.8 in |
Environment |
|
Temperature range | - 40 °C to 85 °C / - 40 °F to 185 °F |
Protection class | IP65 |
Measurement |
|
Measurement range | - 50 °C to 250 °C / - 58 °F to 482 °F |
Measurement accuracy including ES411 error | ± 0.2 °C (at Tamb = 25 °C) |
± 0.35 °C (at Tamb = - 40 °C to 85 °C / - 40 °F to 185 °F and Tmeas = - 50 °C to 100 °C / - 58 °F to 212 °F) | |
± 0.5 °C (at Tamb = - 40 °C to 85 °C / - 40 °F to 185 °F and Tmeas = 100 °C to 250 °C / 202 °F to 482 °F) | |
Effective noise | 0.01 °C |
Response time | < 100 ms |
Recommended measurement modules |
|
ES411 - A/D Module with Sensor Supply | |
System requirements |
|
Software | ES400 add-on to INCA v1.3.2 and higher |
ES400 configuration and integration tool for XCP applications v1.3.2 and higher | |
Hardware | ES4xx modules v2.0 and higher |
ES4xx modules v1.x are not compatible, but can be upgraded to v2.x at ETAS | |
Firmware | HSP v9.7.0 and higher |
This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.