Technical Data

Dimensions

Cable length 0.30 m / 1 ft to measurement point
1.60 m / 5.3 ft to ES411 module
Probe size (Ø x L) 26 mm x 70 mm / 1 in x 7.8 in

Environment

Temperature range - 40 °C to 85 °C / - 40 °F to 185 °F
Protection class IP65

Measurement

Measurement range - 50 °C to 250 °C / - 58 °F to 482 °F
Measurement accuracy including ES411 error ± 0.2 °C (at Tamb = 25 °C)
± 0.35 °C (at Tamb = - 40 °C to 85 °C / - 40 °F to 185 °F and Tmeas = - 50 °C to 100 °C / - 58 °F to 212 °F)
± 0.5 °C (at Tamb = - 40 °C to 85 °C / - 40 °F to 185 °F and Tmeas = 100 °C to 250 °C / 202 °F to 482 °F)
Effective noise 0.01 °C
Response time < 100 ms

Recommended measurement modules

ES411 - A/D Module with Sensor Supply

System requirements

Software ES400 add-on to INCA v1.3.2 and higher
ES400 configuration and integration tool for XCP applications v1.3.2 and higher
Hardware ES4xx modules v2.0 and higher
ES4xx modules v1.x are not compatible, but can be upgraded to v2.x at ETAS
Firmware HSP v9.7.0 and higher

This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.