Technical Data

 

Size and Weight

Dimensions (HxWxD) 51.5 x 40 x 142 mm / 2.0 x 1.6 x 5.6 in
37.5 x 40 x 129 mm / 1.5 x 1.6 x 5.1 in (tapered rear)
Weight 350 g / 0.77 lb

Environment

Temperature range -40 °C to +120 °C (-40 °F to +248 °F) (operation)
-40 °C to +125 °C (-40 °F to +257 °F) (storage)
Protection class IP67 (with cables connected)
Altitude Up to 5,000 m /16,400 ft
Tested for Mechanical shock, vibration, fall, temperature shock, temperature alteration, storage in humid-ity, salt fog attack, impact from flying rocks, according to DIN EN 60068 res. ISO 16750

Power supply

Operating voltage 5 V to 50 V DC (-40 °C to +85 °C / -40 °F to +185 °F),
6 V to 50 V DC (+85 °C to +120 °C / +185 °F to +248 °F)
Power consumption (at 12 V) 1.8 W typ. (operation without load),
< 25 mW (stand-by)
Reverse voltage protection; Load dump protection Via Cables CBEP410 / 415 / 420/ 430 / 450

Host interface

Ethernet connection and protocol 100 Base-T, Full-Duplex required, XCP-on-UDP/IP
IP address Dynamic via INCA or configuration tool (default 192.168.40.44)

Inputs

Channels 4, each with separate sensor supply
Input measurement ranges (MR) ±100 mV, ±1 V, ±10 V, ±60 V for diff. input voltage Vin
Over voltage protection ±100 V continuous, all MR
Sampling rate 0.5 Samples/s to 10 kSamples/s, configurable per channel [1]
Resolution 16 bit
Anti-aliasing filter (in hardware) 4th order Butterworth, 10 kHz corner frequency
Software filter[1] Digital FIR Butterworth 8th order, bypass possible, 5 kHz max. corner frequency
Electrical isolation of inputs Channel to channel and channel to supply
Maximum common mode voltage ±(100 V - [Vin]) channel to supply ground [1],
Vin ≤±60 V
Input impedance > 2 MΩ II < 400 pF (±10 V, ±60 V)
> 10 MΩ II < 300 pF ( ±1 V, ±100 mV)

Sensor supply output

Output voltage +5 V to +15 V DC or Off, individually adjustable per channel, common ground with power supply, resolution < 1 mV
Output current ≤30 mA per channel, overcurrent protected (200 mA)

Accuracy

Ripple of output voltage < 10 mV peak to peak
Accuracy of output voltage ±10 mV over the whole output voltage range
Measurement Error (MR: 100 mV) ±[0.1 % + 80 ppm/K x |T - 25 °C|] x MR ±0.1 % x Vin
Measurement Error (MR: 1 V) ±[0.05 % + 8 ppm/K x |T - 25 °C|] x MR ±0.05 % x Vin
Measurement Error (MR: 10 V) ±[0.03 % + 3.6 ppm/K x |T -25 °C|] x MR ±0.05 % x Vin
Measurement Error (MR: 60 V) ±[0.03 % + 60 ppm/K x |T - 25 °C|] x MR ±0.2 % x Vin

Support by ETAS Software

Supported by INCA V5.3 and higher, INTECRIO V3.0 and higher, ES400 configuration and integration tool for XCP applications

Notes

[1] 60 V maximum for use inside the US.

This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.