Size and weight

Dimensions (HxWxD) 63 mm x 215 mm x 230 mm / 2.47 in x 8.46 in x 9.06 in (housing)
Weight 2.9 kg / 6.44 lb

Environment

Temperature range -40°C to +70°C / -40 °F to +158 °F (operation)
-40°C to +85°C / -40 °F to +185 °F (storage)
Relative humidity 85 % (Operation) 95 % (Storage), non-condensing
Robustness Mechanical shock, vibration, free fall, temperature change, in accordance with ISO 16750 and DIN EN 60068
Protection class IP44
Operating altitude Maximum 5,000 m above sea level

Supply

Operating voltage 7 V – 29 V DC
Operating Current Range 5 A (Max) in operation (12 V DC)
Energy management (wake-up/standby) Power-on/off when Ethernet traffic starts/stops (PC or upstream module on/off)
Configurable: "On" when CAN/CAN FD traffic starts
Standby current Range 17 mA (typ.) at 12 V DC
25 mA (max.)
Protection Reverse polarity protection up to 32 V, overload protection

Interfaces

Gigabit Ethernet 1x 100/1000Base-T (HOST) (incl. IEEE1588 (PTP) TimeSync)
Fast Ethernet[1] 1x XETK ECU interface (incl. IEEE1588 (PTP) TimeSync). Alternatively: 1x 10/100Base-T for connecting measurement and interface modules (incl. ETAS TimeSync.), e. g. ES4xx, ES523, ES6xx
Support of IEEE 1588 (PTP) time synchronization
Gigabit Ethernet[1] 1x 10/100/1000Base-T for connecting measurement and interface modules (incl. IEEE1588 TimeSync)
Automotive Ethernet[1] 3x 100 Base-T1 (OPEN Alliance BroadR-Reach), all of them can be used for BR_XETKs (incl. IEEE1588 (PTP) TimeSync).

Device interfaces

Power Supply For connected ES4xx/ES6xx Measurement Modules and XETKs
Synchronization Resolution: 1 μs

Bus interfaces

5 x CAN/CAN FD/ CAN XL , 1 X LIN
CAN/CAN FD 5 independent CAN interfaces: CAN FD or CAN High-Speed, CAN protocols CAN 2.0a and 2.0b, CAN Transceiver: NXP TJA1462 ( signal improvement capability using SIC), CAN: 1Mbit/ sec (Max Speed) 8 Bytes (Payload), CAN FD SIC: 5Mbit/ sec (higher number of nodes and sub-topology), 8Mbit/ sec (point to point connection) 64 Bytes (Payload), CAN XL: 8 Mbit/ sec 2048 Bytes (Payload)
LIN 1 independent interface LIN V2.1, LIN Transceiver: MCZ33661EF

Status displays

LEDs Status of operation, interfaces and synchronization

Wakeup Management

Standby mode : System automatically switches to standby mode when none of the host ethernet or AE nodes, CAN-FD, CAN and LIN nodes detects any data traffic signal
Wakeup mode : System automatically switches to On mode when either host ethernet or Data traffic or at least one of the AE nodes, CAN-FD, CAN and LIN node detects any data traffic

Compatible hardware

PC/ETAS upstream modules PC with Ethernet connection, ES820 Drive Recorder
ETAS downstream modules ES523, ES592, ES593-D, ES595, ES88x Network and Interface Modules; ES4xx, ES6xx Measurement Modules; ES910.3 Prototyping and Interface Module; ES930 Multi-I/O Module or ES600.2

Supported ETAS software

ETAS INCA Supported onward INCA V7.4.3
Firmware Update Supported onward HSP V13.7.0
3rd party SW support Integration of device via BOA libraries in 3rd party Tools https://www.etas.services/en/downloadcenter/18102.php

Notes

[1] Supports the connection of external XCP-on-Ethernet devices

This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.