Size and Weight |
|
Dimensions (HxWxD) | 23 mm x 45 mm x 87 mm / 0.91 in x 1.77 in x 3.43 in (housing) |
Length of the integrated USB cable | 1,5 m / 4.92 ft |
Weight | 150 g / 5.291 oz (with cable) |
Environment |
|
Temperature range | -40 °C to +70 °C / -40 °F to +158 °F (operation) -40 °C to +85 °C / -40 °F to +185 °F (transport and storage) |
Relative humidity range | 15 % to 95 %, non-condensing |
Power supply |
|
Power consumption | Power provided by USB port of the host PC or notebook |
CAN/CAN-FD interface |
|
Number of channels | 1 |
Mode of operation | CAN or CAN FD operation for the CAN FD Port can be individually configured in the software |
Support for CAN FD variants | In CAN FD mode, the protocol variant ISO/non-ISO for the CAN FD channel can be configured in the software |
Protocols for CAN/CAN FD | XCP, UDS (ISO 14229/ISO 15765), CAN Monitoring, OBD-on-CAN (ISO 15765-4) |
Protocols for CAN | CCP, KWP-on-CAN (ISO 14230/ISO 15765) |
CAN Transceiver (physical layer) | TJA1044G |
Maximum baud rate on CAN | 1 Mbit/s |
Maximum baud rate on CAN-FD | 5 Mbit/s (Higher baud rates are possible under optimum environmental and topology conditions) |
Electrical isolation | Interface is electrically isolated |
LIN interface |
|
Number of channels | 1 |
LIN version | 2.1 |
Mode of operation | Master/slave |
Electrical isolation | Interface is electrically isolated |
Synchronous data acquisition |
|
INCA synchronizes the data with signals from measurment modules (for example, from ES4xx or ES6xx modules) and ECUs with ETK or XETK interfaces that have been acquired using the ES584 module | |
PC interface |
|
USB | USB 2.0, High Speed |
Host system requirements |
|
Operating system | Windows® 7, Windows® 8 , Windows® 10 |
Status display |
|
LEDs | Operating state, interfaces |
Software support |
|
ETAS INCA V7.2 or higher, ETAS ODX-LINK and ETAS ODX-FLASH V7.2 or higher, ETAS HSP V11.6.0 or higher, BUSMASTER | |
Delivery content |
|
USB CAN FD and LIN bus interface ES584, Y-CAN cable, CD with driver installations and user manual |
This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.