Technical Data

 

Size and Weight

Dimensions (HxWxD) 23 mm x 45 mm x 87 mm / 0.91 in x 1.77 in x 3.43 in (housing)
Length of the integrated USB cable 1,5 m / 4.92 ft
Weight 150 g / 5.291 oz (with cable)

Environment

Temperature range -40 °C to +70 °C / -40 °F to +158 °F (operation)
-40 °C to +85 °C / -40 °F to +185 °F (transport and storage)
Relative humidity range 15 % to 95 %, non-condensing

Power supply

Power consumption Power provided by USB port of the host PC or notebook

CAN/CAN-FD interface

Number of channels 1
Mode of operation CAN or CAN FD operation for the CAN FD Port can be individually configured in the software
Support for CAN FD variants In CAN FD mode, the protocol variant ISO/non-ISO for the CAN FD channel can be configured in the software
Protocols for CAN/CAN FD XCP, UDS (ISO 14229/ISO 15765), CAN Monitoring, OBD-on-CAN (ISO 15765-4)
Protocols for CAN CCP, KWP-on-CAN (ISO 14230/ISO 15765)
CAN Transceiver (physical layer) TJA1044G
Maximum baud rate on CAN 1 Mbit/s
Maximum baud rate on CAN-FD 5 Mbit/s (Higher baud rates are possible under optimum environmental and topology conditions)
Electrical isolation Interface is electrically isolated

LIN interface

Number of channels 1
LIN version 2.1
Mode of operation Master/slave
Electrical isolation Interface is electrically isolated

Synchronous data acquisition

INCA synchronizes the data with signals from measurment modules (for example, from ES4xx or ES6xx modules) and ECUs with ETK or XETK interfaces that have been acquired using the ES584 module

PC interface

USB USB 2.0, High Speed

Host system requirements

Operating system Windows® 7, Windows® 8 , Windows® 10

Status display

LEDs Operating state, interfaces

Software support

ETAS INCA V7.2 or higher, ETAS ODX-LINK and ETAS ODX-FLASH V7.2 or higher, ETAS HSP V11.6.0 or higher, BUSMASTER

Delivery content

USB CAN FD and LIN bus interface ES584, Y-CAN cable,
CD with driver installations and user manual

This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.