Technical Data

ES891.2 ES892.2

Size and weight

Dimensions (HxWxD) 63 mm x 215 mm x 230 mm (2.47 in x 8.46 in x 9.05 in)
Weight 2.9 kg / 6.4 lbs

Environment

Temperature range -40 °C to +70 °C / -40 °F to +158 °F (operation)
-40 °C to +85 °C / -40 °F to +185 °F (storage)
Relative humidity 85 % (Operation) 95 % (Storage), non-condensing
Tested for Mechanical shock, vibration, fall, temperature alteration, according to EN 60068 and ISO 16750
Protection class IP44
Altitude Maximum 5000 m / 16.400 ft height above sea level
Standby current Range 17 mA (typ.) at 12 V DC
25 mA (max.)
Operating Current Range 5 A (Max) in operation (12 V DC)

Power supply

Operating voltage 7 V – 29 V DC
Power consumption at 12 V DC Typically 2.2 A in operation and 12 mA in standby
Energy management (wake-up / standby) Power-on/off when Ethernet traffic starts/stops (PC or upstream module on/off).
Configurable: Power-on when CAN/ CAN FD/ FlexRay traffic starts
Protection Reverse voltage protection up to 32 V, load dump protection

Host interface

Gigabit Ethernet 1x 100/1000Base-T
Fast Ethernet 1x XETK ECU interface. Alternatively: 1x 10/100Base-T for the connection of measurement and interface modules
Gigabit Ethernet 2x FETK ECU interfaces with host-side XCP-on-Ethernet support.
With the help of an adapter cable, ETKs of type ETK-S20.1 and ETK-S21.1 can be connected.
Alternatively: 2x 10/100/1000Base-T for the connection of measurement and interface modules

Device interfaces

Power supply Of connected ES4xx / ES6xx measurement modules and XETKs
Synchronization Resolution: 1 µs

Bus interfaces

5 x CAN/CAN FD/ CAN XL or 3 x CAN/CAN FD/ CAN XL and 1 x Flex Ray , 1 X LIN 5 x CAN/CAN FD/ CAN XL or 3 x CAN/CAN FD/ CAN XL and  1 X LIN
CAN/CAN FD/ CAN XL [1] 5 channels high-speed CAN (2.0 A and 2.0B).
Transfer of CAN FD data frames up to 64 Byte and rates up to 5 Mbit/s
CAN Transceiver: NXP TJA1462 ( signal improvement capability using SIC)
CAN: 1Mbit/ sec (Max Speed) 8 Bytes (Payload), CAN FD SIC: 5Mbit/ sec (higher number of nodes and sub-topology), 8Mbit/ sec (point to point connection) 64 Bytes (Payload), CAN XL: 8 Mbit/ sec 2048 Bytes (Payload)
FlexRay[1] 1 FlexRay V2.1 interface with 2 channels A and B or one additional internal node for synchronizing the FlexRay bus
Flex Ray Transceiver: NXP TJA1082, 254 Bytes ( Max. Payload), 10 Mbit/ sec (Max Speed)
LIN 1 channel LIN V2.2A
LIN Transceiver: MCZ33661EF

Status display

LEDs Status of operation, interfaces and synchronization

Compatible hardware

PC/ ETAS upstream modules PC with Ethernet port, ES820 Drive Recorder
ETAS downstream modules ES523, ES592, ES593-D, ES595, ES600.2, and ES88x Network and Interface Modules, ES4xx and ES6xx Measurement Modules, ES910.3 Prototyping and Interface Module, ES930 Multi-I/O Module as well as the XETK- and BR-XETK (with CBEB105 BroadR-Reach Media Converter)

Support by software

ETAS INCA Supports onward INCA V7.4.3
Firmware Update Supported onward HSP V13.7.0
3rd party SW support Enables 3rd party usage (BOA, XCP) https://www.etas.services/en/downloadcenter/18102.php

Wakeup Management

Standby mode : System automatically switches to standby mode when none of the host ethernet or AE nodes, CAN-FD, CAN, CAN XL FlexRay and LIN nodes detects any data traffic signal Standby mode : System automatically switches to standby mode when none of the host ethernet or AE nodes, CAN-FD, CAN and LIN nodes detects any data traffic signal
Wakeup mode : System automatically switches to On mode when either host ethernet or Data traffic or at least one of the AE nodes, CAN-FD, CAN, CAN XL FlexRay and LIN node detects any data traffic Wakeup mode : System automatically switches to On mode when either host ethernet or Data traffic or at least one of the AE nodes, CAN-FD, CAN and LIN node detects any data traffic

Note

[1] When the FlexRay interface of the ES891 module is not used, the ES891 module provides five CAN / CAN FD channels also.

This product has been developed and released for use in automotive applications. For usage in other domains please contact your ETAS representative.