Données techniques

Size and Weight

Dimensions (HxWxD) 45 mm x 127 mm x 160 mm / 1.75 in x 5.0 in x 6.3 in (housing)
Weight Approx. 0.8 g / approx. 1.8 lbs

Environment

Temperature range -40 °C to +70 °C / -40 °F to +158 °F (operation)
-40 °C to +85 °C / -40 °F to +185 °F (storage)
Relative humidity 0% to 85 % (Operations) , non-condensing
0% to 95 % (Storage)
Tested for Mechanical shock, vibration, fall, temperature shock, temperature alteration, according to EN 60068 and ISO 16750
Ingress protection IP30
Operating Current Range 7 A Max. (module max. 3A; o/p current per ETH 2 A max.)

Power supply

Operating voltage 7 V to 29 V DC
Power consumption (at 14.4 V) 500 mA at 14.4 V (typical, operation)
20 mA at 14.4 V (typical, stand-by)
Power management (wake-up / stand-by) Power-on/off when Ethernet traffic starts/stops (PC or upstream module on/off), power-on when CAN traffic starts
Protection Reverse voltage protection, load dump protection

Host interface

Firmware Update Support starts from HSP V2.1.6

Ethernet interfaces

Connection and protocols TCP/IP, Ethernet Switching (Layer 2), IEEE802.3
Time synchronization Time resolution: 1 μs
Fast Ethernet 2 x 10 / 100BASE-T Ethernet (Downstream), ETH1, ETH2 supports ETAS device synchronization mechanism
Ethernet 1 x 10 / 100BASE-T (Upstream)
Host PC Supports 100Mbit/s, full duplex RJ45 connection with 32-bit data bus
Power supply of connected devices ES4xx and ES6xx measurement modules, XETKs

ECU and bus interfaces

Operating Mode: Basic, Compatibility, Advanced Protocol Transfer : Single Mode supports speed of 8Mbit/s Block Mode supports either 8Mbit/s or 100 Mbit/s
CAN 4 High Speed channels. For ES720 drive recorder applications, 2
channels thereof provide for buffering of CAN frames and
wake-up.
CAN Transceiver TJA1040
Protocol CAN Standard (V2.0a) or Extended Format (V2.0b), CAN: 1MBaud (Max Speed) 8 Bytes (Payload) CAN Interface 1 and CAN Interface 2 supports Wakeup
CAN Pre-Buffering Boot time to start of recording: 100 ms

Status display

LEDs Operation, interfaces, synchronization

Compatible hardware

PC / ETAS Upstream Module Desktop or Laptop PC with Ethernet port, ES592, ES593-D, ES595, and ES600 Network and Interface Modules
ETAS Downstream Module ES592, ES593-D, ES595, ES600 Network and Interface Modules, ES4xx and ES6xx Measurement Modules, ES910 Prototyping and Interface Module, XETK

Support by ETAS software

INCA INCA V6.2.1 and up
API (C libraries) Provide for integration with 3rd party applications

Ce produit a été développé et validé en vue d’applications automobiles. Pour autre domaine d’usage, merci de contacter votre contact chez ETAS.