ISOLAR, Middleware Solution, RTAAUTOSAR, ISOLAR-A, ISOLAR-B, RTA-RTEFAQ / Use CaseAUTOSAR: "System Signal Group" vs. "ISignal Group" AUTOSAR: "System Signal Group" vs. "ISignal Group"

What is the difference between "System Signal Group" and "ISignal Group"? In this article, Steffen Roser (Support Engineer at ETAS) provides short answers to this question and the reference to the specific AUTOSAR document.

13.07.2018
ASCETASCET V6.0, ASCET V6.1, ASCET V6.2, ASCET V6.3, ASCET V6.4FAQ / Use CaseASCET Experiment Error: Target code does not respond to L1 messages. ASCET Experiment Error: Target code does not respond to L1 messages.

In this article, Steffen Roser (Support Engineer at ETAS) provides example root cause for an error message you may see in ASCET Experiment Environment during rapid prototyping.

12.07.2018
ISOLAR, Middleware Solution, RTA, Virtualization TechnologyISOLAR-EVE, RTA-OSFAQ / Use CaseInternal error in strscan.rb Internal error in strscan.rb

Receiving an error message when trying to generate RTA-OS code in ISOLAR-EVE on Windows 10? In this article, Steffen Roser (Support Engineer at ETAS) shows one possible root cause and the according solution.

12.07.2018
ISOLARAUTOSAR, ISOLAR-A, ISOLAR-BFAQ / Use CaseISOLAR-A - DBC Import: java.net.MalformedURLException: unknown protocol: ar ISOLAR-A - DBC Import: java.net.MalformedURLException: unknown protocol: ar

When importing a DBC file there may appear an error "java.net.MalformedURLException...". In this article, Steffen Roser (Support Engineer at ETAS) explains 2 root causes and how to fix them.

12.07.2018
ISOLAR, Middleware Solution, RTAAUTOSAR, ISOLAR-A, ISOLAR-B, RTA-RTEFAQ / Use CaseAUTOSAR: How to create SOME/IP configuration AUTOSAR: How to create SOME/IP configuration

Ethernet supports the service oriented communication through Service Oriented Middleware over Internet Protocol (SOME/IP). In this article, Steffen Roser (Support Engineer at ETAS), provides a step by step guide to set up an AUTOSAR project with SOME/IP configuration in ETAS ISOLAR-A.

11.07.2018
ASCETASCET-DEVELOPERFAQ / Use CaseASCET-DEVELOPER: How to transfer project ASCET-DEVELOPER: How to transfer project

In case you want to transfer you ASCET-DEVELOPER project to another computer: In this articel, Steffen Roser (Support Engineer at ETAS), guides you step by step through the procedure.

26.06.2018
EHOOKSEHOOKSFAQ / Use CaseEHOOKS Error: The ECU binary (HEX) file ... does not match the ASAM-MCD 2MC file EHOOKS Error: The ECU binary (HEX) file ... does not match the ASAM-MCD 2MC file

In case you receive the error message "The ECU binary (HEX) file ... does not match the ASAM-MCD 2MC file" in EHOOKS: In this article, Steffen Roser (Support Engineer at ETAS), provides instructions how to handle this issue.

22.06.2018
ASCETASCET V6.0, ASCET V6.1, ASCET V6.2, ASCET V6.3, ASCET V6.4FAQ / Use CaseASCET: Header files are missing ASCET: Header files are missing

In the generated code there is only 1 header file generated while we expected several header files (one for each single C code file): In this article, Steffen Roser (Support Engineer at ETAS) shows the 2 most frequent root causes and how to change the behavior.

20.06.2018
EVE, INTECRIO, Virtualization TechnologyINTECRIO, ISOLAR-EVEFAQ / Use CaseExperiment Environment: Where is tab Signal Generator? Experiment Environment: Where is tab Signal Generator?

In case you are missing tab Signal Generator in Experiment Environment: In this article, Steffen Roser (Support Engineer at ETAS), provides further information.

20.06.2018
ISOLARAUTOSAR, ISOLAR-A, ISOLAR-BFAQ / Use CaseISOLAR-A: Adapter generation via command line ISOLAR-A: Adapter generation via command line

Do you want to use ISOLAR-A functionality via command line interface for AUTOSAR development? In this article, Steffen Roser (Support Engineer at ETAS) points you to documentation regarding ISOLAR-A command line commands.

04.06.2018
ISOLARAUTOSAR, ISOLAR-A, ISOLAR-BFAQ / Use CaseISOLAR-A: Create and map many RTE Ports for CAN ISOLAR-A: Create and map many RTE Ports for CAN

After DBC import you manually create hundreds of signals one by one, and then map each one to a port one by one? In this article, Steffen Roser (Support Engineer at ETAS), provides a simple algorithm regarding how to automate this use case with ISOLAR. 

04.06.2018