Produktfamilie / Kategorie
|
Produkt / Thema
|
Typ
|
Titel
|
Datum
|
ASCET | ASCET V6.2, ASCET V6.3, ASCET V6.4 | FAQ / Use Case | [ ASCET ] WARNING(WMdl00): please note: the value "false" of project option "Force Parenthesis for Binary Logical Operators" is obsolete
WARNING (WMdl00): please note: the value "false" of project option "Force Parenthesis for Binary Logical Operators" is obsolete
Do you receive warning messages regarding obsolete project option values when you build code from your model?
In this article, Steffen Roser (Support Engineer at ETAS), describes how to get rid of these warnings. | 12.09.2017 |
ASCET | ASCET V6.2, ASCET V6.3, ASCET V6.4 | FAQ / Use Case | [ ASCET ] ERROR (YBdl22): method must be defined; need a return value
ERROR (YBdl22): method must be defined; need a return value
When building code from ASCET model there may appear following error message:
"ERROR(YBdl22): method must be defined; need a return value".
In this article, Steffen Roser (Support Engineer at ETAS) describes how to solve this error message. | 07.09.2017 |
ASCET | ASCET V6.2, ASCET V6.3, ASCET V6.4 | FAQ / Use Case | [ ASCET ] ERROR (YBdl51): missing argument connection for method ... at block ...
ERROR(YBdl51): missing argument connection for method ... at block ...
When building code from your model in ASCET, it may happen that you receive following message:
ERROR(YBdl51): missing argument connection for method at block .
In this article, Steffen Roser (Support Engineer at ETAS) describes how to fix this behaviour. | 07.09.2017 |
ASCET | ASCET V6.2, ASCET V6.3, ASCET V6.4 | FAQ / Use Case | [ ASCET ] Generation of documentation aborted. SGDummyDrawingWindow >> methodAliasName
Generation of documentation aborted. SGDummyDrawingWindow>>methodAliasName
Creating a fancy looking document from your ASCET models is easy.
Just go to Tools > Documentation. In case you get the error 'SGDummyDrawingWindow>>methodAliasName' during generation document: This behavior is fixed in ASCET V6.4.
In this article, Steffen Roser (Support Engineer at ETAS) describes a workaround. | 07.09.2017 |
ASCET | ASCET V6.2, ASCET V6.3, ASCET V6.4 | FAQ / Use Case | [ ASCET ] WARNING (WBdl9): empty sequence call at block
WARNING (WBdl9): empty sequence call at block
When building code from your model in ASCET, it may happen that you receive following message: WARNING(WBdl9): empty sequence call at block .
In this article, Steffen Roser (Support Engineer at ETAS) describes how to fix this behaviour. | 07.09.2017 |
ASCET | ASCET V6.2, ASCET V6.3, ASCET V6.4 | FAQ / Use Case | [ ASCET ] WARNING (WMdl204): deprecated feature: BDE temp variables
WARNING (WMdl204): deprecated feature: BDE temp variables
When generation code from ASCET model there may appear a warning regarding a deprecated feature ("BDE temp variables").
In this article, Steffen Roser (Support Engineer at ETAS) describes how to switch off this warning message. | 07.09.2017 |
EVE, ISOLAR, Virtualization Technology | AUTOSAR, ISOLAR-EVE | FAQ / Use Case | In ISOLAR-EVE: Problem Occurred - The Visual Studio compiler version is not found
Wanted to generate code for an virtual electronic control unit (VECU) in ISOLAR-EVE but received an error message. In this article, Steffen Roser (Support Engineer for Software Engineering at ETAS), shows how to solve this situation. | 11.08.2017 |
ASCET | ASCET V6.4 | FAQ / Use Case | How to create a System Constant in ASCET
System constants are used like constants, and also created as define statements. Unlike constants, system constants can be implemented. They are always explicitly visible in the generated code. In this article, Steffen Roser (Support Engineer for Software Engineering at ETAS), describes how to create a system constant in ASCET. | 10.08.2017 |
ASCET | ASCET V6.4 | FAQ / Use Case | How to create a Variant Array or Variant Matrix in ASCET
The size of an array or matrix is determined when the element is created. In addition, ASCET allows the determination of variants in array/matrix sizes via system constants. In this article, Steffen Roser (Support Engineer Software Engineering at ETAS), describes how to create a variant array or a variant matrix in ASCET. | 10.08.2017 |
ASCET | ASCET V6.2, ASCET V6.3, ASCET V6.4 | FAQ / Use Case | In ASCET: ERROR(MMdl20): identifier "SYSTEMCONSTANT" not declared
In case you did receive the error message when trying to execute code generation in ASCET: In this article, Steffen Roser (Support Engineer for Software Engineering at ETAS), provides information regarding a solution, a workaround and background information. | 10.08.2017 |
ISOLAR | AUTOSAR, ISOLAR-A | FAQ / Use Case | [ ISOLAR ] How to get to the Tab Entity to Task Mapping
How to get to the Tab Entity to Task Mapping
In case you want to edit entity to task mapping in your AUTOSAR project and cannot remember how to navigate to the according editor.
In this article, Steffen Roser (Support Engineer for Software Engineering at ETAS), shows how to get there. | 10.08.2017 |