INCA V7.2 Service Pack 1

Functions at a Glance

  • COM-API – Support of 32-bit and 64-bit clients
  • Variable Selection Dialog (VSD) – Add function list to experiment tree
  • INCA-MCE – Measurement and Calibration Embedded
    • FETK support
    • Variable Selection
  • XCP – Slave detection on Ethernet
  • XCP – ODT Optimization and measurement data consistency

COM-API – Support of 32-bit and 64-bit clients

In addition to 32-bit clients, INCA now can be remotely controlled also by 64-bit clients. Beginning with MATLAB® R2015b, INCA supports the 64-bit version of MATLAB®.

Variable Selection Dialog (VSD) – Add function list to experiment tree

For variable configuration, the Variable Selection Dialog provides a sources tab that allows the user to filter variables by ECU functions.

INCA-MCE – Measurement and Calibration Embedded

INCA-MCE (Measurement and Calibration Embedded) now supports the new ETAS ECU Interfaces FETK-T1.0, FETK-S1.0, and FETK-S2.0.

The Variable Selection Dialog of INCA-MCE shows both measurements and calibration variables that are configured in the INCA experiment or remotely by the test bench.

XCP – Slave detection on Ethernet

The slave detection feature enables the user to search for connected XCP slaves on Ethernet. INCA finds all slaves that support the GET_SLAVE_ID command of XCP 1.3. INCA detects the required parameters (IP address and port number) to establish the communication.

XCP – ODT optimization and measurement data consistency

To optimize measurements on the ECU side, INCA supports additional optimization methods in combination with data consistency checks for XCP.

A2L / ECU OM_DEFAULT OM_ODT_ TYPE_16 OM_ODT_ TYPE_32 OM_ODT_ TYPE_64 OM_ODT_ ALIGNMENT OM_MAX_ ENTRY_SIZE

Consistency on ODT

Map to INCA V7.1 behavior
(Event Consistency +
OM_DEFAULT)

INCA V7.2.0

INCA V7.2.0

 

INCA V7.2.0  

INCA V7.2 SP1

 

INCA V7.2 SP1

 

Consistency on DAQ

INCA V7.2.0

INCA V7.2 SP1

INCA V7.2 SP1

 

INCA V7.2 SP1

 

INCA V7.2 SP1

 

INCA V7.2 SP1

 

Consistency on EVENT

INCA V7.1 behavior

INCA V7.2 SP1 

INCA V7.2 SP1

 

INCA V7.2 SP1

 

INCA V7.2.0  

 