Size and Weight |
|
Dimensions (HxWxD) | 45 mm x 127 mm x 160 mm / 1.75 in x 5.0 in x 6.3 in (housing) |
Weight | 0.8 Kg / 1.8 lbs |
Environment |
|
Temperature range | -40 °C to +70 °C / -40 °F to +158 °F (operation) |
-40 °C to +85 °C / -40 °F to +185 °F (storage) | |
Relative humidity | 0% to 85 % (Operations) , non-condensing |
0% to 95 % (Storage) | |
Tested for | Mechanical shock, vibration, fall, temperature shock, temperature alteration, according to EN 60068 and ISO 16750 |
Ingress protection | IP30 |
Operating Current Range | 5 A Max. (module max. 3A; o/p current per ETH 2 A max.) |
Power supply |
|
Operating voltage | 7 V to 29 V DC |
Power consumption (at 14.4 V) | 500 mA at 14.4 V (typical, operation) |
20 mA at 14.4 V (typical, stand-by) | |
Power management (wake-up / stand-by) | Power-on/off when Ethernet traffic starts/stops (PC or upstream module on/off) |
Protection | Reverse voltage protection, load dump protection |
Ethernet interfaces |
|
Connection and protocols | 10/100 Base-T; TCP/IP |
Time synchronization | Time resolution: 1 μs |
Power supply of connected devices | ES4xx and ES6xx measurement modules, XETKs |
ECU and bus interfaces |
|
2 x Independent CAN, 2 x Independent LIN, 1 x FlexRay node with two independent channel | |
ETK | Operating Mode : Basic, Compatibility, Advanced, Protocol Transfer : Single Mode supports speed of 8Mbit/s Block Mode supports either 8Mbit/s or 100 Mbit/s |
LIN | LIN Transceiver: MCZ33661EF, Specification: LIN V2.1, Operating Mode: LIN Master |
FlexRay | Bus Driver: Philips TJA 1082, Payload: 254 bytes (Max.), Specification: V2.1 |
CAN | 2 channels, optionally High Speed (up to 1 MBaud) or Low Speed |
High Speed CAN | CAN Transceiver: TJA1040, Speed: Max. 1 MBaud with a bus length of 20 m |
Low Speed CAN | CAN Transceiver: TJA1054A, Speed: Max. 125 kBaud |
Status display |
|
LEDs | Operation, interfaces, synchronization |
Compatible hardware |
|
PC / ETAS Upstream Module | Desktop or Laptop PC with Ethernet port, ES592, ES593-D, ES595, and ES600 Network and Interface Modules |
ETAS Downstream Module | ES592, ES593-D, ES595, ES600 Network and Interface Modules, ES4xx and ES6xx Measurement Modules, ES910 Prototyping and Interface Module, XETK |
Support by ETAS software |
|
INCA | INCA V6.2.1 and up INCA-LIN V6.2.3 and up |
Firmware Update | Support starts from HSP V2.1.6 |
Host interface |
|
Fast Ethernet | 2 x 10 / 100BASE-T Ethernet (Downstream), ETH1, ETH2 supports ETAS device synchronization mechanism |
Ethernet | 1 x 10 / 100BASE-T (Upstream) |
Host PC | Supports 100Mbit/s, full duplex RJ45 connection with 32-bit data bus |
Protocol | TCP/IP, Ethernet Switching (Layer 2), IEEE802.3 |
Ce produit a été développé et validé en vue d’applications automobiles. Pour autre domaine d’usage, merci de contacter votre contact chez ETAS.