Size and weight

Dimensions (HxWxD) 63 mm x 215 mm x 230 mm / 2.47 in x 8.46 in x 9.06 in (housing)
Weight 2.9 kg / 6.44 lb

Environment

Temperature range -40 °C to +70 °C / -40 °F to +158 °F (operation)
-40 °C to +85 °C / -40 °F to +185 °F (storage)
Relative humidity 85 % (Operation)  95 % (Storage), non-condensing
Robustness Mechanical shock, vibration, free fall, temperature change, in accordance with ISO 16750 and DIN EN 60068
Protection class IP44
Operating altitude Maximum 5,000 m above sea level
Standby current Range 17 mA (typ.) at 12 V DC
25 mA (max.)

Supply

Operating voltage 7 V – 29 V DC
Operating Current Range 5 A (Max) in operation (12 V DC)
Current consumption at 12 V DC Typically, 2.2 A in operation and 17 mA in standby at 12 V operating voltage
Energy management (wake-up / standby) Power-on / off when Ethernet traffic starts / stops (PC or upstream module on/off)
Configurable: "On" when CAN/CAN FD traffic starts
Protection Reverse polarity protection up to 32 V, overload protection

Interfaces

Gigabit Ethernet 1x 100/1000 Base-T (HOST), (inkl. IEEE1588 (PTP) TimeSync)
Fast Ethernet[1] 1x XETK ECU interface. Alternatively: 1x 10/100 Base-T for connecting measurement and interface modules (incl. ETAS TimeSync.), e. g. ES4xx, ES523, ES6xx
Gigabit Ethernet[1] 1x 10/100/1000 Base-T for connecting measurement and interface modules (incl. IEEE1588 TimeSync.)
Automotive Ethernet[1] 4x 100 Base-T1 (OPEN Alliance BroadR-Reach) usable for BR_XETKs. When using internal TAP, 2x BR_XETKs can be connected.

Device interfaces

Power Supply For connected ES4xx/ES6xx Measurement Modules and XETKs
Synchronization Resolution: 1 μs

Bus interfaces

5 x CAN/CAN FD/ CAN XL , 1 X LIN
CAN/ CAN FD/ CAN XL 5 independent CAN interfaces: CAN FD or CAN High-Speed, CAN protocols CAN 2.0a and 2.0b.
CAN Transceiver: NXP TJA1462 ( signal improvement capability using SIC), CAN: 1Mbit/ sec (Max Speed) 8 Bytes (Payload), CAN FD SIC: 5Mbit/ sec (higher number of nodes and sub-topology), 8Mbit/ sec (point to point connection) 64 Bytes (Payload), CAN XL: 8 Mbit/ sec 2048 Bytes (Payload)
LIN 1 independent interface LIN V2.1
LIN Transceiver: MCZ33661EF

Status displays

LEDs Status of operation, interfaces and synchronization

Wakeup Management

Standby mode: System automatically switches to standby mode when none of the host ethernet or AE nodes, CAN-FD, CAN and LIN nodes detects any data traffic signal
Wakeup mode: System automatically switches to On mode when either host ethernet or Data traffic or at least one of the AE nodes, CAN-FD, CAN and LIN node detects any data traffic

Compatible hardware

PC/ETAS upstream modules PC with Ethernet connection, ES820 Drive Recorder
ETAS downstream modules ES523, ES592, ES593-D, ES595, ES88x Network and Interface Modules; ES4xx and ES6xx Measurement Modules; ES910.3 Prototyping and Interface Module; ES930 Multi-I/O Module or ES600.2

Supported ETAS software

HSP V11.9; for Ethernet Monitoring with AUTOSAR PDU: from V11.13.0
ETAS INCA Supported onward INCA V7.4.0
Firmware Update Supported onward HSP V13.7.0